From b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b Mon Sep 17 00:00:00 2001 From: priyanka Date: Wed, 24 Jun 2015 15:03:17 +0530 Subject: initial commit / add all books --- 2063/CH10/EX10.6/10_6.sce | 24 ++++++++++++++++++++++++ 1 file changed, 24 insertions(+) create mode 100755 2063/CH10/EX10.6/10_6.sce (limited to '2063/CH10/EX10.6') diff --git a/2063/CH10/EX10.6/10_6.sce b/2063/CH10/EX10.6/10_6.sce new file mode 100755 index 000000000..d46d7f7a9 --- /dev/null +++ b/2063/CH10/EX10.6/10_6.sce @@ -0,0 +1,24 @@ +clc +clear +//Input data +T2=298;//Maximum temperature at which ammonia refrigerating system works in K +T1=263;//Minimum temperature at which ammonia refrigerating system works in K +mf=5;//Fluid flow rate in kg/min +sf1=0.5443;//Liquid entropy at 298 K in kJ/kg K +sf2=1.1242;//Liquid entropy at 263 K in kJ/kg K +hfg1=1297.68;//Latent heat at 298 K in kJ/kg +hfg2=1166.94;//Latent heat at 263 K in kJ/kg +hf1=135.37;//Liquid enthalpy at point 1 in graph in kJ/kg +hf2=298.9;//Liquid enthalpy at point 2 in graph in kJ/kg +TR=210;//One tonne refrigeration in TR + +//Calculations +s2=sf2+(hfg2/T2);//Entropy at point 2 in kJ/kg +x1=(s2-sf1)/(hfg1/T1);//Dryness fraction at point 1 +h1=hf1+(x1*hfg1);//Enthalpy at point 1 in kJ/kg +h=h1-hf2;//Heat extracted of refrigerating effect produced per kg of refrigerant in kJ/kg +ht=mf*h;//Total heat extracted at a fluid flow rate of 5 kg/min in kJ/min +C=ht/TR;//Capacity of refrigerating in TR + +//Output +printf('The capacity of refrigerator is %3.0f TR',C) -- cgit