From b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b Mon Sep 17 00:00:00 2001 From: priyanka Date: Wed, 24 Jun 2015 15:03:17 +0530 Subject: initial commit / add all books --- 2006/CH8/EX8.1/ex8_1.sce | 25 +++++++++++++++++++++++++ 1 file changed, 25 insertions(+) create mode 100755 2006/CH8/EX8.1/ex8_1.sce (limited to '2006/CH8/EX8.1/ex8_1.sce') diff --git a/2006/CH8/EX8.1/ex8_1.sce b/2006/CH8/EX8.1/ex8_1.sce new file mode 100755 index 000000000..f4ed1e1e9 --- /dev/null +++ b/2006/CH8/EX8.1/ex8_1.sce @@ -0,0 +1,25 @@ +clc; +TH=311.06; // Source temperature in degree celcius +pb=10; // Boiler pressure in MPa +TL=32.88; // Sink temperature in degree celcius +pc=5; // Condenser pressure in kPa +// From steam tables at pb +h2=1407.56; // specific enthalpy in kJ/kg +h3=2724.7; // specific enthalpy in kJ/kg +s2=3.3596; // specific entropy in kJ/kg K +s3=5.6141; // specific entropy in kJ/kg K +// From steam tables at pc +hf=137.82; hfg=2423.7; // specific enthalpy in kJ/kg +sf=0.4764; sfg=7.9187; // specific entropy in kJ/kg K +x1=(s2-sf)/sfg; // quality of steam at state 1 +x4=(s3-sf)/sfg; // quality of steam at state 4 +h1=hf+x1*hfg; // specific enthalpy at state 1 +h4=hf+x4*hfg; // specific enthalpy at state 4 +wT=h3-h4; // Turbine work +wC=h2-h1; // Compressor work +wnet=wT-wC; // Net work output +qH=h3-h2; // Heat added +rw=wnet/wT; // Ratio of net work to trbine work +eff_th=wnet/qH; // Thermal efficiency +SSC=3600/wnet; // specific steam consumption +disp ("kg/kWh",SSC,"specific steam consumption =","%",eff_th*100,"Thermal efficiency =",rw,"Ratio of net work to trbine work ="); -- cgit