From b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b Mon Sep 17 00:00:00 2001 From: priyanka Date: Wed, 24 Jun 2015 15:03:17 +0530 Subject: initial commit / add all books --- 1775/CH6/EX6.9/Chapter6_Example9.sce | 35 +++++++++++++++++++++++++++++++++++ 1 file changed, 35 insertions(+) create mode 100755 1775/CH6/EX6.9/Chapter6_Example9.sce (limited to '1775/CH6/EX6.9/Chapter6_Example9.sce') diff --git a/1775/CH6/EX6.9/Chapter6_Example9.sce b/1775/CH6/EX6.9/Chapter6_Example9.sce new file mode 100755 index 000000000..2e12a43a1 --- /dev/null +++ b/1775/CH6/EX6.9/Chapter6_Example9.sce @@ -0,0 +1,35 @@ +//Chapter-6, Illustration 9, Page 316 +//Title: Refrigeration cycles +//============================================================================= +clc +clear + +//INPUT DATA +T2=40;//Temperature at point 2 in oC +T1=-5;//Temperature at point 1 in oC +h2=367.155;//Enthalpy at point 2 from F-12 tables in kJ/kg +sg=1.55717;//Entropy from F-12 tables in kJ/kg-K +s1=1.54057;//Entropy at point 1 from F-12 tables in kJ/kg-K +sf=0.98311;//Entropy from F-12 tables in kJ/kg-K +hf=195.394;//Enthalpy from F-12 tables in kJ/kg +hfg=153.934;//Enthalpy from F-12 tables in kJ/kg +h4=238.533;//Enthalpy at point 4 from F-12 tables in kJ/kg +h4s=218;//Enthalpy at point 4 with subcooling from F-12 tables in kJ/kg + +//CALCULATIONS +x1=(s1-sf)/(sg-sf);//Quality factor +h1=hf+(x1*hfg);//Enthalpy at point 1 from refrigerant-12 tables in kJ/kg +COPns=(h1-h4)/(h2-h1);//Co-efficient of performance with no subcooling +COPs=(h1-h4s)/(h2-h1);//Co-efficient of performance with subcooling + +//OUTPUT +mprintf('COP with no subcooling is %3.3f \n COP with subcooling is %3.3f',COPns,COPs) + + + + + + + + +//==============================END OF PROGRAM================================= -- cgit