From 7f60ea012dd2524dae921a2a35adbf7ef21f2bb6 Mon Sep 17 00:00:00 2001 From: prashantsinalkar Date: Tue, 10 Oct 2017 12:27:19 +0530 Subject: initial commit / add all books --- 1319/CH6/EX6.11/6_11.sce | 64 ++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 64 insertions(+) create mode 100644 1319/CH6/EX6.11/6_11.sce (limited to '1319/CH6/EX6.11/6_11.sce') diff --git a/1319/CH6/EX6.11/6_11.sce b/1319/CH6/EX6.11/6_11.sce new file mode 100644 index 000000000..2d8ae3b83 --- /dev/null +++ b/1319/CH6/EX6.11/6_11.sce @@ -0,0 +1,64 @@ +//Swinburne test on a dc shunt motor + +clc; +clear; + +V=500; +I=5; +Rf=250; +Ra=0.5; + +P=V*I; +If=V/Rf; + +Ia=I-If; + +Pfc=(If^2)*Rf;// Field Copper Loss + +Pac=(Ia^2)*Ra; // Armature Copper Loss + +Pil=P-Pfc-Pac;// Iron loss + +// Generator + +Vg=500; +Ig=100; + +Pog=Vg*Ig; // Power Output + +Iag=Ig+If; //Armature current + +Pgac=(Iag^2)*Ra; // Armature Copper loss + +slg=0.01*Pog;//stray loss + +Pgtl=Pgac+Pfc+slg+Pil; // Total losses + +effg=Pog*100/(Pog+Pgtl); + +// Motor + +Vm=500; +Im=100; + +Pim=Vm*Im; // Power input to the motor + +Iam=Ig-If; // Armature current + +Pmac=(Iam^2)*Ra; // Armature Copper Loss + +Pom=Pim-Pmac-Pil-Pfc;// Ouput of the motor +slm=0.01*Pom;// Stray loss + +Pmtl=Pmac+Pil+Pfc+slm; // Total loss of the motor + +effm=(Pom-slm)*100/(Pim); + + +printf('i) The Efficiency of the machine as a generator delivering 100A at 500V = %g percent \n',effg) + +printf('ii) The Efficiency of the machine as a motor having a line current 100A at 500V = %g percent \n',effm) + + + + -- cgit