summaryrefslogtreecommitdiff
path: root/608/CH20/EX20.16/20_16.sce
diff options
context:
space:
mode:
Diffstat (limited to '608/CH20/EX20.16/20_16.sce')
-rwxr-xr-x608/CH20/EX20.16/20_16.sce22
1 files changed, 22 insertions, 0 deletions
diff --git a/608/CH20/EX20.16/20_16.sce b/608/CH20/EX20.16/20_16.sce
new file mode 100755
index 000000000..9cca90770
--- /dev/null
+++ b/608/CH20/EX20.16/20_16.sce
@@ -0,0 +1,22 @@
+//Problem 20.16: A 200 kVA rated transformer has a full-load copper loss of 1.5 kW and an iron loss of 1 kW. Determine the transformer efficiency at full load and 0.85 power factor.
+
+//initializing the variables:
+S = 200000; // in VA
+Pc = 1500; // in Watt
+Pi = 1000; // in Watt
+pf = 0.85; // power factor
+
+//calculation:
+//Efficiency = output power/input power = (input power—losses)/input power
+//Efficiency = 1 - losses/input power
+//Full-load output power = V*I*pf
+Po = S*pf
+//Total losses
+Pl = Pc + Pi
+//Input power = output power + losses
+PI = Po + Pl
+//efficiency
+eff = 1-(Pl/PI)
+
+printf("\n\n Result \n\n")
+printf("\n the transformer efficiency at full load is %.4f", eff) \ No newline at end of file