diff options
Diffstat (limited to '3751/CH16/EX16.1/Ex16_1.sce')
-rw-r--r-- | 3751/CH16/EX16.1/Ex16_1.sce | 28 |
1 files changed, 28 insertions, 0 deletions
diff --git a/3751/CH16/EX16.1/Ex16_1.sce b/3751/CH16/EX16.1/Ex16_1.sce new file mode 100644 index 000000000..2c55c1fe5 --- /dev/null +++ b/3751/CH16/EX16.1/Ex16_1.sce @@ -0,0 +1,28 @@ +//Fluid Systems - By Shiv Kumar +//Chapter 16- Hydraulic Power and Its Transmissions +//Example 16.1 +//To Find the Maximum Power Available at the Outlet of Pipe. + clc + clear + +//Given Data:- + d=300; //Diameter of the Pipe, mm + l=3000; //Length of the Pipe, m + H=400; //Total Head at Inlet, m + f=0.005; + +//Data Required:- + rho=1000; //Density of Water, Kg/m^3 + g=9.81; //Acceleration due to gravity, m/s^2 + +//Computations:- + //Condition for Maximum Power transmission + hf=H/3; //m + V=sqrt(hf*(2*g*d/1000)/(4*f*l)); //m/s + Q=(%pi/4)*(d/1000)^2*V; //Discharge, m^3/s + Pmax=rho*g*Q*(H-hf)/1000; //Maximum Power Available at Outlet of Pipe, kW + + +//Results:- + printf("The Maximum Power Available at Outlet of Pipe=%.3f kW",Pmax) //The answer vary due to round off error + |