@@ -0,0 +1,28 @@
+//Fluid Systems - By Shiv Kumar
+//Chapter 16- Hydraulic Power and Its Transmissions
+//Example 16.1
+//To Find the Maximum Power Available at the Outlet of Pipe.
+ clc
+ clear
+
+//Given Data:-
+ d=300; //Diameter of the Pipe, mm
+ l=3000; //Length of the Pipe, m
+ H=400; //Total Head at Inlet, m
+ f=0.005;
+
+//Data Required:-
+ rho=1000; //Density of Water, Kg/m^3
+ g=9.81; //Acceleration due to gravity, m/s^2
+
+//Computations:-
+ //Condition for Maximum Power transmission
+ hf=H/3; //m
+ V=sqrt(hf*(2*g*d/1000)/(4*f*l)); //m/s
+ Q=(%pi/4)*(d/1000)^2*V; //Discharge, m^3/s
+ Pmax=rho*g*Q*(H-hf)/1000; //Maximum Power Available at Outlet of Pipe, kW
+
+
+//Results:-
+ printf("The Maximum Power Available at Outlet of Pipe=%.3f kW",Pmax) //The answer vary due to round off error
+