+// A Texbook on POWER SYSTEM ENGINEERING
+// A.Chakrabarti, M.L.Soni, P.V.Gupta, U.S.Bhatnagar
+// DHANPAT RAI & Co.
+// SECOND EDITION
+
+// PART II : TRANSMISSION AND DISTRIBUTION
+// CHAPTER 5: MECHANICAL DESIGN OF OVERHEAD LINES
+
+// EXAMPLE : 5.4 :
+// Page number 199
+clear ; clc ; close ; // Clear the work space and console
+
+// Given data
+a = 110.0 // Cross-sectional area(sq.mm)
+w_c = 844.0/1000 // Weight of conductor(kg/m)
+U = 7950.0 // Ultimate strength(kg)
+L = 300.0 // Span(m)
+s = 2.0 // Factor of safety
+wind = 75.0 // Wind pressure(kg/m^2)
+h = 7.0 // Ground clearance(m)
+d = 2.79 // Diameter of copper(mm)
+n = 7.0 // Number of strands
+
+// Calculations
+dia = n*d // Diameter of conductor(mm)
+w_w = wind*dia/1000.0 // Horizontal wind force(kg)
+w = (w_c**2+w_w**2)**0.5 // Resultant force(kg)
+T = U/2.0 // Allowable tension(m)
+l = L/2.0 // Half-span(m)
+D = w*l**2/(2*T) // Distance(m)
+height = h+D // Height above ground at which the conductors should be supported(m)
+
+// Results
+disp("PART II - EXAMPLE : 5.4 : SOLUTION :-")
+printf("\nHeight above ground at which the conductors should be supported = %.2f metres", height)