diff options
author | priyanka | 2015-06-24 15:03:17 +0530 |
---|---|---|
committer | priyanka | 2015-06-24 15:03:17 +0530 |
commit | b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b (patch) | |
tree | ab291cffc65280e58ac82470ba63fbcca7805165 /3035/CH3 | |
download | Scilab-TBC-Uploads-b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b.tar.gz Scilab-TBC-Uploads-b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b.tar.bz2 Scilab-TBC-Uploads-b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b.zip |
initial commit / add all books
Diffstat (limited to '3035/CH3')
-rwxr-xr-x | 3035/CH3/EX3.1/Ex3_1.sce | 38 |
1 files changed, 38 insertions, 0 deletions
diff --git a/3035/CH3/EX3.1/Ex3_1.sce b/3035/CH3/EX3.1/Ex3_1.sce new file mode 100755 index 000000000..639c14101 --- /dev/null +++ b/3035/CH3/EX3.1/Ex3_1.sce @@ -0,0 +1,38 @@ + +// Variable Declaration +P = 5.0 //Power(MW) +pf = 0.8 //lagging power factor +d = 15.0 //Distance of line(km) +J = 4.0 //Current density(amp per mm^2) +r = 1.78*10**(-8) //Resistivity(ohm-m) +kV_1 = 11.0 //Permissible voltage level(kV) +kV_2 = 22.0 //Permissible voltage level(kV) + +// Calculation Section +I_1 = (P*10**3)/((3)**(0.5) * (kV_1) * pf) //Load current(A) +area_1 = I_1/J //Cross-sectional area of the phase conductor(mm^2) +volume_1 = 3 * (area_1/10**6) * (d*10**3) //Volume of conductors material(m^3) +R_1 = r * (d*10**3)/(area_1 * (10**-6)) //Resistance per phase(ohm) +PL_1 = 3 * (I_1**2) * (R_1*10**(-3)) //Power loss(kW) + +I_2 = (P*10**3)/((3)**(0.5) * (kV_2) * pf) //Load current(A) +area_2 = I_2/J //Cross-sectional area of the phase conductor(mm^2) +volume_2 = 3 * (area_2/10**6) * (d*10**3) //Volume of conductors material(m^3) +R_2 = r * (d*10**3)/(area_2 * (10**-6)) //Resistance per phase(ohm) +PL_2 = 3 * (I_2**2) * (R_2*10**(-3)) //Power loss(kW) +area_ch = (area_1-area_2)/area_1*100 //Change in area of 22kV level from 11 kV level(%) +vol_ch = (volume_1-volume_2)/volume_1*100 //Change in volume of 22kV level from 11 kV level(%) +loss_ch = (PL_1-PL_2)/PL_1*100 //Change in losses of 22kV level from 11 kV level(%) + +// Result Section +printf('For 11 kV level :') +printf('Cross-sectional area of the phase conductor = %d mm^2' ,area_1) +printf('Volume of conductors material = %.2f m^3' ,volume_1) +printf('Power loss = %.2f kW' ,PL_1) +printf('\nFor 22 kV level :') +printf('Cross-sectional area of the phase conductor = %d mm^2' ,area_2) +printf('Volume of conductors material = %.2f m^3' ,volume_2) +printf('Power loss = %.2f kW' ,PL_2) +printf('\nConductor size has decreased by %.f percent in 22 kV level' ,area_ch) +printf('Conductor volume has decreased by %.f percent in 22 kV level' ,vol_ch) +printf('Conductor losses has decreased by %.f percent in 22 kV level' ,loss_ch) |