{ "metadata": { "name": "CHAPTER5" }, "nbformat": 3, "nbformat_minor": 0, "worksheets": [ { "cells": [ { "cell_type": "heading", "level": 1, "metadata": {}, "source": [ "Chapter5 : Introduction to Convection" ] }, { "cell_type": "heading", "level": 3, "metadata": {}, "source": [ "Example 5.1 Page NO. 248" ] }, { "cell_type": "code", "collapsed": false, "input": [ "\n", "Cp=871\n", "Gamma=1.3\n", "\n", "Cv=Cp/Gamma\n", "dT=20\n", "m=5\n", "Qp=m*Cp*dT\n", "Qv=m*Cv*dT\n", "\n", "print\" The heat required at constant pressure is \",Qp/1000,\"kj\"\n", "print\"The heat required at constant volume is \",Qv/1000,\"kj\"\n" ], "language": "python", "metadata": {}, "outputs": [ { "output_type": "stream", "stream": "stdout", "text": [ " The heat required at constant pressure is 87 kj\n", "The heat required at constant volume is 67.0 kj\n" ] } ], "prompt_number": 4 }, { "cell_type": "heading", "level": 3, "metadata": {}, "source": [ "Example 5.2 Page NO.250" ] }, { "cell_type": "code", "collapsed": false, "input": [ "\n", "T1_Fr=-50\n", "T2_Fr=-40\n", "rou1_Fr=1.546*1000\n", "rou2_Fr=1.518*1000\n", "\n", "beta_Fr=-(rou1_Fr-rou2_Fr)/(rou1_Fr*(T1_Fr-T2_Fr))\n", "beta_acc_Fr=2.63e-3 # the accurate value of volumetric thermal expansion coefficient for Freon-12\n", "error_Fr=(beta_acc_Fr-beta_Fr)*100/beta_acc_Fr\n", "T1_He=366\n", "T2_He=477\n", "rou1_He=0.13280\n", "rou2_He=0.10204\n", "beta_He=-(rou1_He-rou2_He)/(rou1_He*(T1_He-T2_He))\n", "\n", "print\"The volumetric thermal expansion coefficient calculated for Freon-12 is \",round(beta_Fr,6),\"1/K\"\n", "print\"The error introduced in the case of Freon-12 is percent\",round(error_Fr,0),\"percent\"\n", "print\"The volumetric thermal expansion coefficient calculated for Freon-12 is \",round(beta_He,6),\"1/K\"\n" ], "language": "python", "metadata": {}, "outputs": [ { "output_type": "stream", "stream": "stdout", "text": [ "The volumetric thermal expansion coefficient calculated for Freon-12 is 0.001811 1/K\n", "The error introduced in the case of Freon-12 is percent 31.0 percent\n", "The volumetric thermal expansion coefficient calculated for Freon-12 is 0.002087 1/K\n" ] } ], "prompt_number": 1 }, { "cell_type": "code", "collapsed": false, "input": [], "language": "python", "metadata": {}, "outputs": [] } ], "metadata": {} } ] }