"cell_type": "code",
"collapsed": false,
"input": [
"",
"import math",
"#Variable declaration",
"C=1000*10**-12; #Switche capacitor value in farads",
"R=1000; #resistance in ohms",
"",
"#calculation",
"T=R*C; #Time period",
"f=1/T; #Frequency at which switch should operate",
"f=math.ceil(f)",
"#Result",
"print('Frequency at which each switch should operate(in hertz) is \\n %d' %f)",
"print('Duty cycle should be 50%')"
],
"language": "python",
"outputs": [
{
"output_type": "stream",
"stream": "stdout",
"text": [
"Frequency at which each switch should operate(in hertz) is ",
" 1000000",
"Duty cycle should be 50%"
]
}
],
"prompt_number": 1
}
]
}
]
}