{ "metadata": { "name": "Chapter_18" }, "nbformat": 2, "worksheets": [ { "cells": [ { "cell_type": "markdown", "source": [ "

Chapter 18: Programmable Analog Arrays

" ] }, { "cell_type": "markdown", "source": [ "

Example 18.1, Page Number: 588

" ] }, { "cell_type": "code", "collapsed": false, "input": [ "", "import math", "#Variable declaration", "C=1000*10**-12; #Switche capacitor value in farads", "R=1000; #resistance in ohms", "", "#calculation", "T=R*C; #Time period", "f=1/T; #Frequency at which switch should operate", "f=math.ceil(f)", "#Result", "print('Frequency at which each switch should operate(in hertz) is \\n %d' %f)", "print('Duty cycle should be 50%')" ], "language": "python", "outputs": [ { "output_type": "stream", "stream": "stdout", "text": [ "Frequency at which each switch should operate(in hertz) is ", " 1000000", "Duty cycle should be 50%" ] } ], "prompt_number": 1 } ] } ] }